Skip links

EBH 1 Basic circuits in building and wiring installation technology

Alpha Technical Solutions Inc.

EBH 1 Basic circuits in building and wiring installation technology

Training contents:

  • Selection of fuse elements
  • On-off circuit with and without earth-contact socket outlet
  • Series circuit with and without earth-contact socket outlet
  • Two-way/changeover circuit with and without earth-contact socket outlet
  • Multi-way/crossover circuit with and without junction boxes
  • Stairway circuitry
  • Analysis of wiring installation plans
Basic equipment set, consisting of:
1
Line circuit breaker, 2-pole type B6, 6 A
Line circuit breaker, 2-pole type B6, 6 ASE2501-1L
1
RCCB residual current circuit breaker 30mA, 2-pole
RCCB residual current circuit breaker 30mA, 2-poleSE2501-1S
2
On, off and two-way changeover switch
On, off and two-way changeover switchSE2501-3A
1
Two circuit single-interruption switch
Two circuit single-interruption switchSE2501-3C
1
Two-way double-pole reversing switch
Two-way double-pole reversing switchSE2501-3D
3
Single pushbutton
Single pushbuttonSE2501-3E
1
Lighting module, 3-fold, 230 V
Lighting module, 3-fold, 230 VSE2501-3J
2
Socket outlet with earthing contact
Socket outlet with earthing contactSE2501-3M
1
Remote relay switch with stairwell function, programmable
Remote relay switch with stairwell function, programmableSE2501-3N
2
Storage tray for SE boxes, reinforced, (10 boxes)  310 x 45 x 700 mm
Storage tray for SE boxes, reinforced, (10 boxes) 310 x 45 x 700 mmST7004-2B
Media:
1
Interactive Lab Assistant: Basic wiring installation circuits
Interactive Lab Assistant: Basic wiring installation circuitsSO2801-4H
Power supply:
1
Mains connection box 230 V, single phase
Mains connection box 230 V, single phaseSE2501-1D
Measuring instruments:
1
Voltage, phase + continuity tester with field direction indicator, max. 690V
Voltage, phase + continuity tester with field direction indicator, max. 690VLM8554
1
TRMS digital multimeter MetraHit 2+, CAT III
TRMS digital multimeter MetraHit 2+, CAT IIILM2323
1
Power meter, 1-phase REG
Power meter, 1-phase REGSE2501-2E
Accessories:
3
Branching box 5 x 4 socket outlets
Branching box 5 x 4 socket outletsSE2501-3H
1
Set of safety measurement cables, 4mm (23 leads), for Instrain
Set of safety measurement cables, 4mm (23 leads), for InstrainSO5148-1M
Accessories:
1
Punched hole panel, interchangeable, for 1200 mm panel mounting frames
Punched hole panel, interchangeable, for 1200 mm panel mounting framesST8003-5Q
1
Mobile aluminum experiment stand, 3 levels, power strip with 6 sockets,(1250 x 1970 x 700 mm)
Mobile aluminum experiment stand, 3 levels, power strip with 6 sockets,(1250 x 1970 x 700 mm)ST7200-4C

 

This website uses cookies to improve your web experience.