Skip links

EBI 1 CONTACTOR CIRCUITS 24V

How to develop and set up a process control system with functional operation control is the training focus for the following topics:

  • Creation of circuit diagrams
  • Configuration of motor protection relays as per the motor’s rating plate
  • Contactor-type latching circuit
  • Contactor-type circuit with malfunction signal trigger in the event of controlled motor overload and with stored malfunction signal
  • Contactor-type circuit with off-delay relay
  • Contactor-type circuit with on-delay relay
  • Pulsed contactor-type circuits
  • Contactor-type reverse control with contactor interlocking
  • Contactor-type reverse control with contactor and pushbutton interlocking
  • End-point control using mechanical end-position limit switches plus reversal of direction
  • Star-delta circuit configuration
  • Automatic star-delta circuit
  • Automatic star-delta reversing circuit
Equipment set comprising the following:
1
Line circuit breaker, 2-pole type B6, 6 A
Line circuit breaker, 2-pole type B6, 6 ASE2501-1L
1
Line-circuit-breaker type B16, 4-pole, 16 A
Line-circuit-breaker type B16, 4-pole, 16 ASE2501-1P
1
RCCB residual current circuit breaker 30mA, 4-pole
RCCB residual current circuit breaker 30mA, 4-poleSE2501-1T
1
Emergency OFF button
Emergency OFF buttonSE2501-1Y
1
Button, three-way
Button, three-waySE2501-7A
3
Push button, single, black
Push button, single, blackSE2501-7B
2
Limit switch 1 N.O.& 1 N.C. contacts
Limit switch 1 N.O.& 1 N.C. contactsSE2501-7C
1
Indicator light, 3 ways, red, yellow, green, 24 V
Indicator light, 3 ways, red, yellow, green, 24 VSE2501-7E
1
Indicator light, 3 ways, green, 24 V
Indicator light, 3 ways, green, 24 VSE2501-7H
1
Main switch, 4-pole
Main switch, 4-poleSE2501-7J
4
Main contactor with 1 n.o./2 n.c. with auxiliary contact, 24 V
Main contactor with 1 n.o./2 n.c. with auxiliary contact, 24 VSE2501-7M
3
Auxiliary contactor, 4 N.O. & 4 N.C., 24V
Auxiliary contactor, 4 N.O. & 4 N.C., 24VSE2501-7Q
1
Time relay, delayed response, 24 V
Time relay, delayed response, 24 VSE2501-7U
1
Time relay, off-delayed 24....230V AC/DC
Time relay, off-delayed 24….230V AC/DCSE2501-7T
1
Motor protection circuit breaker 0.4 - 0.63 A
Motor protection circuit breaker 0.4 – 0.63 ASE2501-7W
1
Motor protection circuit breaker 0.6 - 1.0 A
Motor protection circuit breaker 0.6 – 1.0 ASE2501-7X
1
Motor protection relay 0.63 - 1 A
Motor protection relay 0.63 – 1 ASE2501-7Y
1
Multi-function relay 24-230 V
Multi-function relay 24-230 VSE2501-7Z
1
Three-phase asynchronous motor, 0.3 kW n=1400 (400V/690V)
Three-phase asynchronous motor, 0.3 kW n=1400 (400V/690V)SE2683-1G
3
Storage tray for SE boxes, reinforced, (10 boxes)  310 x 45 x 700 mm
Storage tray for SE boxes, reinforced, (10 boxes) 310 x 45 x 700 mmST7004-2B
Media:
1
Interactive Lab Assistant: Schützschaltungen für Drehstrommotoren (B)
Interactive Lab Assistant: Schützschaltungen für Drehstrommotoren (B)SO2801-4F
Power supply:
1
Mains connection box, 3x400V, three-phase
Mains connection box, 3x400V, three-phaseSE2501-1G
1
Mains connection box 24 V
Mains connection box 24 VSE2501-1K
Measuring instruments:
1
Voltage, phase + continuity tester with field direction indicator, max. 690V
Voltage, phase + continuity tester with field direction indicator, max. 690VLM8554
1
Voltmeter REG
Voltmeter REGSE2501-2A
1
Ammeter REG
Ammeter REGSE2501-2C
1
Power meter, 3-phase REG
Power meter, 3-phase REGSE2501-2G
Accessories:
1
Set of safety measurement cables, 4mm (53 leads)
Set of safety measurement cables, 4mm (53 leads)SO5148-1D
Accessories:
1
Punched hole panel, interchangeable, for 1200 mm panel mounting frames
Punched hole panel, interchangeable, for 1200 mm panel mounting framesST8003-5Q
1
Mobile aluminum experiment stand, 3 levels, power strip with 6 sockets,(1250 x 1970 x 700 mm)
Mobile aluminum experiment stand, 3 levels, power strip with 6 sockets,(1250 x 1970 x 700 mm)ST7200-4C

 

This website uses cookies to improve your web experience.